Electrical Safety Tester
]
type:
Electrical Safety Tester
brand:GW
model:
GPE-745
supplier:
Xing Chuang Li Gao Instrument & Meter
brief product description:
GPE-745 Electrical Safety Tester: 200VA AC Test Capacity AC/DC Withstanding Voltage Test & Insulation Resistance Test & Ground Bond Test Arc Detection
specification
GPE-745 Electrical Safety Tester
AC HI-POT |
| Voltage Range | 0.100 ~ 5.000kV |
| Voltage Resolution | 5V |
| Voltage Regulation | 1% + 5 V |
| Voltage Accuracy | ±(1% of reading ±10 V) |
| Max. Current Sourcing | 30mA ~ 40mA (above 500V, maximum test time 180sec) 0.1mA ~ 29.99mA (above 500V, continuous test) 0.1mA ~ 40mA (below 500V, continuous test) |
| Current Limit | 0.10 ~ 40mA, 0.02mA/step |
| Current Accuracy | ±(1% of reading ±80μA) |
DC HI-POT |
| Voltage Range | 0.100kV ~ 6.000kV |
| Voltage Resolution | 5V |
| Voltage Regulation | 1% + 5 V |
| Voltage Accuracy | ±(1% of reading ±10 V) (above 500V) |
| Max. Current Sourcing | 0.1mA ~ 10mA (above 500V, continous test) 0.1mA ~ 2mA (below 500V, continuous test) |
| Current Limit | 0.1mA ~ 10mA, 0.01mA/step |
| Current Accuracy | ±(1% of reading ±50μA) |
INSULATION RESISTANCE |
| DC Voltage | 50V/100V/500V/1000V |
| Resistance Range | 1 ~ 9900MΩ(500V,1000V) 1 ~ 2000MΩ(50V,100V) |
| Resistance Accuracy | 50V/100V 1MΩ ~ 50MΩ: ±(5% of reading ±1count) 51MΩ ~ 200MΩ: ±(10% of reading ±1count) 201MΩ ~ 1990MΩ: ±(20% of reading ±1count) |
| | 500V/1000V 1MΩ ~ 500MΩ: ±(5% of reading ±1count) 501MΩ ~ 2000MΩ: ±(10% of reading ±1count) 2001MΩ ~ 9900MΩ: ±(20% of reading ±1count) |
GROUND BOND |
| Voltage Range | Max. 8V (DC) |
| Current Range | 3 ~ 42A |
| Current Resolution | 0.02A |
| Current Accuracy | 1% of reading 0.2A(3A~8A) |
| Ground Bond | 1% of reading 50mA(9A~42A) |
| Resistance Test | 0 ~ 600mΩ |
| Resistance Resolution | 0.1mΩ |
| Resistance Accuracy | ±(1% of reading 3 mΩ) |
| Test Method | Four terminals test mode |
RAMP TIME & TEST TIME |
| AC Hi-Pot Ramp/Test Time | 0.0 ~ 999.9 seconds |
| DC Hi-Pot Ramp/Test Time | 0.0 ~ 999.9 seconds |
| Insulation Resistance Ramp/Test Time | 0.0 ~ 999.9 seconds |
| Ground Bond Ramp/Test Time | 0.0 ~ 999.9 seconds |
ARC DETECT |
| Detect Current | 40 level (1 ~ 40mA) |
INTERFACE |
| Remote I/O | Standard |
| RS-232C | Standard |
| Real Panel Output | Standard |
| GPIB | Option |
| Scanner Box | Option (HSB-001-1 : 8ch HV+8ch GB ; HSB-001-2 : 16ch HV) |
| POWER SOURCE | |
| | AC 100V/120V/220V/230V ± 10%, 50/60Hz |
ACCESSORIES |
| | User manual x 1 Power cord x 1 Test lead GHT-105A x 1, GTL-115 x 1 |
| DIMENSIONS & WEIGHT | |
| | 330(W) x 149(H) x 446(D) mm Approx.15kg |