SPF80 Generator/ Counter
]
type:
SPF80 Generator/ Counter
brand:Sample
model:
SPF80
supplier:
Xing Chuang Li Gao Instrument & Meter
brief product description:
SPF80 Generator/ Counter:The SPF80 Digital Synthesized Function Generator/Counter is a generator based on direct digital synthesis (DDS) techniques
specification
SPF80 Generator/ Counter
FrequencyRange | 1μHz ~ 80MHz (Sine) 1μHz ~ 40MHz (Square and TTL) 1μHz~100kHz (Othe Waves) |
AmplitudeRange | 1mVp-p~10Vp-p (50Ω load) 2mVp-p~20Vp-p (open circuit ) (f≤40MHz) 1mVp-p~2Vp-p (50MΩ load) 2mVp-p~4Vp-p ( open circuit ) (f >40MHz) |
Output waveforms | SIN,Square,Pulse,Triangle,Ramp,etc more than 27 waveforms . It also Output Sweep,Burst,FSK,PSK,FM,AM waveforms. |
Distortion of Sine Wave | ≤ 0.1% (f:20Hz~100kHz) |
Arbitrary Wave Length | 8~16000 |
Amplitude resolution | 12bits |
Sample Rate | 200Msa/s |
Harmonic Distortion of Sine Wave | ≤-50dBc (f ≤ 5MHz) ≤-45dBc (f ≤ 10MHz) ≤-40dBc (f ≤ 20MHz) ≤-35dBc (f ≤ 40MHz) ≤-30dBc (f > 40MHz) |
Rise/Fall Time of Square | ≤ 15ns |
Duty Fctor of Pulse Wave | 0.1%~99.9% (Frequency≤10kHz) |
1%~99% (10kHz~100kHz) |
Frequency Resolution | 1μHz |
Frequency Accuracy | ≤±5×10-6 |
Aplitude Resolution | 2μVp-p , 1μVp-p (50Ω) |
Amplitude Accuracy | ≤± 1%+0.2mV (sine wave relative to 1kHz) |
Amplitude Flatness | For amplitude ≤ 2Vpp: ±3% ( f ≤ 5 MHz) ±10% ( f ≤ 40 MHz) For amplitude >2Vpp: ±5% ( f ≤ 5 MHz) ±10% ( f ≤ 20 MHz) ±20% ( f ≤ 40 MHz) ±1 dBm (40 MHz < f ≤ 80 MHz) |
OffsetRange | ± 10 V ( f ≤ 40 MHz) ± 2 V ( f ≤ 80 MHz) |
Offset Resolution | 2μVp-p ,1μVp-p (50Ω) |
Offset Error | ±5% of setting +10mV (Ampl. ≤ 2Vpp into open circuit) |
±5% of setting +20mV (Ampl. > 2Vpp into open circuit) |
AM Modulation Depth | 1%~120% 1%~80% (f > 40MHz,Ampl >2Vp-p(open circuit)) |
Phase Range(PSK) | 0.0~360.0° |
Phase Resolution(PSK) | 0.1° |
Arbitrary Wave Module (configurable) | FrequencyRange | 1μHz~100kHz |
Wave length | 8~16000 |
Amplitude resolution | 10bits |
Chanel B Module(configurable) | FrequencyRange | 1μHz~20kHz |
AmplitudeRange | 2mVp-p~20Vp-p |
Distortion of Sine Wave | ≤ 1% ( 2Vp-p,1kHz ) |
Output Impedance | 600Ω±5% |
Rise/Fall time of Square wave | < 10μs |
Phase difference range between CHA and CHB | 0.0~360.0° |
Phase difference Error | -0.5°~+0.5° (f < 2kHz ) |
Output waveforms | SIN,Square,Pulse,Triangle,Ramp. |
Counters | Frequency Measurement | 1Hz~100MHz |
Totalize Capacity | ≤ 4.29 × 109 |
Time base | Frequency | 10MHz |
Stability | ≤± 1 × 10-6 |
Show | 12-digit high brightness VFD display |
Other | Can store /recall 10 group work state. With RS232 interface, and optional GPIB, USB interface |
Dimension | 255mm×370mm×100mm |
Weight | 3.5kg |