MDS-620 Anolog Oscilloscope

]
sendmsg
type: MDS-620 Anolog Oscilloscope
brand:MATRIX
model: MDS-620
supplier: Xing Chuang Li Gao Instrument & Meter


brief product description:

-20MHz Dual Channel -High sensitivity 1mV/DIV -Z Axis Input -CH1 Output -10 times sweep magnification -TV Synchronization, X-Y mode -High luminance, internal graticule Toshiba CRT -Fmax=20MS/s -Store depth:1K × CH2+1K × 2(Reference Memories) Preset triggering function, pre-trigger signal observation -Two channel, two reference waveform display Simultaneous 4 Waveforms Information -The minimum sweeping speed is 10s/DIV, The ration measures ultra low frequency signals -Measu

specification

Vertical system

  • Verticals resolution: 8bits (28point/DIV)
  • Accuracy: ± 3% ± 0.4mm ( × 5MAG: ± 5% ± 0.4mm)
  • Equivalent bandwidth: ± 3% ± 0.4mm( × 5MAG: ± 5% ± 0.4mm) -3dB, Sine Interpolate
  • Interpolation: Sine/Line
  • Horizontal System
  • Maximum Sample Rates: 20MS/s
  • Horizontal resolution: 10bit (100point/DIV)
  • Time base: 0.2 μ s/DIV~10s/DIV ( × 10MAG:1s/DIV~20ns/DIV)
  • Sweep mode: AUTO, NORM, ROLL.
  • Saved waveform expand rate: Maximum 100
  • Trigger
  • Trigger preset: DIV2, 5, 8
  • Acquisition
  • Dual Channel Acquisition:
  • 10s/DIV~0.5 μ s/DIV:CHOP; 0.2ms/DIV~0.2 μ s/DIV: ALT
  • Acquisition Length: 1024Byte/CH
  • Display
  • View time: 0.2s~5s Adjustable
  • Display Memory Length: 1024Byte/CH
  • Reference Memory Length: 1024Byte/CH
  • RS232 interface transfer rate: 19200
  • VERTICAL AXIS
  • Sensitivity: 5mV~5V/DIV,10 steps in 1-2-5 sequence
  • Sensitivity accuracy: ≤ 3% ( × 5 MAG: ≤ 5% )
  • Vernier vertical sensitivity: To 1/2.5 or less of panel-indicated value
  • Frequency bandwidth: DC~20MHz( × 5MAG:DC~7MHz); AC coupling:Low limit frequency 10Hz.(With reference to 100KHz, 8DIV. Frequency response with-3dB.)
  • Rise time: Approx.17.5ns ( × 5MAG:Approx.50ns)
  • Input impedance: Approx.1M Ω /Approx.25pF
  • Square wave characteristics: Overshoot: ≤ 5%(At 10mV/DIV range); Other distortions and other ranges:5% added to the above value
  • Dc balance shift: Adjustable on panel
  • Linearity: ≤± 0.1DIV of amplitude change when waveform of 2DIV at graticule center is moved vertically
  • Vertical modes:
  • CH1 single channel; CH2 single channel;
  • DUAL: CH1 and CH2 are displayed simultaneously. ALT or CHOP selectable at any sweep rate;
  • ADD:CH1+CH2 algebraic addition
  • Chopping repetition frequency: Approx.250KHz
  • Input coupling: AC, GND , DC
  • Maximum input voltage: 300Vpeak (AC: frequency 1KHz or lower);When set probe switch at 1:1, the maximum effective readout is 40Vpp(14Vrms at sine wave),or set probe switch at 10:1,the maximum effective readout is 400Vpp(140Vrms at sine wave).
  • Common mode rejection ratio: 50:1 or better at 50KHz sinusoidal wave.(When sensitivities of CH1 and CH2 are set equally)
  • Isolation between channels(At 5mV/DIV range): > 1000:1 at 50KHz;
  • > 30:1 at 20MHz
  • CH1 signal output: At least 20mV/DIV into a 50 Ω termination. Bandwidth is 50Hz to at least 5MHz
  • CH2 INV BAL: Balanced point variation: ≤ 1DIV(Reference at center graticule)
  • TRIGGERING
  • Triggering source: CH1, CH2, LINE, EXT
  • Coupling: AC: 20Hz to 20MHz
  • Slope: +/-
  • Sensitivity: 20Hz~2MHz: 0.5DIV, TRIG-ALT:2DIV, EXT:200mV; 2~2MHz:1.5DIV TRIG-ALT:3DIV, EXT:800mV;
  • TV: Sync pulse more than 1DIV (EXT:1V)
  • Triggering modes: AUTO; NORM: TV-V: TV-H: (Both TV-V and TV-H synchronize only when the synchronizing signal is negative)
  • EXT triggering signal input: Input impedance/: Approx:1M Ω /approx.25pF; Max.input voltage 300V(DC+AC peak), AC: Frequency not higher than 1KHz
  • HORIZIONTAL AXIS
  • Sweep time: 0.2 μ Sec~0.5Sec/DIV, 20steps in 1-2-5 sequence;
  • Sweep time accuracy: ± 3%; Vernier sweep time control: ≤ 1/2.5 of panel-indicated value;
  • Sweep magnification: 10 times; × 10MAG sweep time accuracy: ±5 %(20nSec~50nSec are uncalibrated);
  • Linearity: ± 3%, × 10MAG: ±5 %(20nSec~50nSec are uncalibrated);
  • Position shift caused by × 10MAG: Within 2DIV. at CRT screen center
  • X-Y MODE: Sensitivity: Same as vertical axis. (X-axis: CH1 input signal;Y-axis:CH2 input signal.); Frequency bandwidth: DC to at least 500KHz; X-Y phase difference: ≤ 3°at DC-50KHz
  • Z AXIS
  • Sensitivity: 5Vp-p (Positive-going signal decreases intensity);
  • Frequency bandwidth: DC~2MHz; Input resistance: Approx.47K Ω ;
  • Maximum input voltage:3V(DC+AC peak, AC frequency ≤ 1KHz)
  • CALIBRATION VOLTAGE
  • Waveform: Positive-going square wave;
  • Frequency: Approx.1KHz; Duty ratio: Within 48:52; Output voltage: 2Vp-p ± 2%;
  • Output impedance: Approx.1K Ω
  • CRT
  • Type: 6-inch rectangular type, internal graticule; Phosphor: P31;Acceleration voltage: Approx.2KV; Effective screen size: 8 × 10DIV(1DIV=10mm(0.39in)); Graticule: Internal; Trace rotation: Provided